Lyt når som helst, hvor som helst

Nyd den ubegrænsede adgang til tusindvis af spændende e- og lydbøger - helt gratis

  • Lyt og læs så meget du har lyst til
  • Opdag et kæmpe bibliotek fyldt med fortællinger
  • Eksklusive titler + Mofibo Originals
  • Opsig når som helst
Start tilbuddet
DK - Details page - Device banner - 894x1036

Case Studies for Optimal Control Schemes of Power System with FACTS Devices and Power Fault Analysis: & Some Stories of Academic Corruption on My Life

Sprog
Engelsk
Format
Kategori

Fakta

This book is divided into three parts related to case Studies for optimal control schemes of power system with FACTS devices, and power system fault analysis, and some stories of academic corruption in my life.

• Part A: Optimal Control Schemes for Power System with FACTS Devices

• Part B. Calculation of Critical Distance in Faulted Meshed Power System

• Part C: Real Stories of Academic Corruption in My Life

I. Part A: Optimal Control Schemes for Power System with FACTS Devices:

Most of the control schemes introduced in the existing papers were designed either for eliminating current harmonics or eliminating voltage flickers or for load flow control. So, this work is devoted to find proper optimal control schemes for a system with series or shunt or series and shunt converters that can provide all functions together. Various optimal control schemes will be designed for systems with series, shunt and series-shunt converters with the objective to control the load flow through lines and to eliminate current harmonics and voltage flickers with different strategies for tracking.

II. Part B. Calculation of Critical Distance in Faulted Meshed Power System

Fault studies form an important part of power system analysis. The problem consists of determining bus voltages and line currents during various types of faults. If the fault location is known the problem can be easily solved. But if the fault location is unkown, it is difficult to solve the problem. If the fault location is known the problem can be easily solved. But if the fault location is unknown, it is difficult to solve the problem. This part provided a proper solution based on Gauess Seidal to find the critical distance in meshed power system

III. Part C: Real Stories of Academic Corruption in My Life

In this part, I will speak about the academic corruption I saw in some universities and academic institutions according to my experience with them.

© 2021 BookRix (E-bog): 9783748771258

Release date

E-bog: 12. januar 2021

Tags

    Andre kan også lide...

    Vælg dit abonnement

    • Over 600.000 titler

    • Download og nyd titler offline

    • Eksklusive titler + Mofibo Originals

    • Børnevenligt miljø (Kids Mode)

    • Det er nemt at opsige når som helst

    Flex

    For dig som vil prøve Mofibo.

    89 kr. /måned
    • 1 konto

    • 20 timer/måned

    • Gem op til 100 ubrugte timer

    • Eksklusivt indhold hver uge

    • Fri lytning til podcasts

    • Ingen binding

    Prøv gratis
    Den mest populære

    Premium

    For dig som lytter og læser ofte.

    129 kr. /måned
    • 1 konto

    • 100 timer/måned

    • Eksklusivt indhold hver uge

    • Fri lytning til podcasts

    • Ingen binding

    Start tilbuddet

    Unlimited

    For dig som lytter og læser ubegrænset.

    149 kr. /måned
    • 1 konto

    • Ubegrænset adgang

    • Eksklusivt indhold hver uge

    • Fri lytning til podcasts

    • Ingen binding

    Start tilbuddet

    Family

    For dig som ønsker at dele historier med familien.

    Fra 179 kr. /måned
    • 2-6 konti

    • 100 timer/måned pr. konto

    • Fri lytning til podcasts

    • Kun 39 kr. pr. ekstra konto

    • Ingen binding

    2 konti

    179 kr. /måned
    Prøv gratis